Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6 with aEvolve Imaging (FOV Extension)

K253584

Canon Medical Systems Corporation · cleared 2026-03-10 · product code OWB · Radiology

Premarket evidence — what FDA accepted

Device typehardware with ml
source quote (p.6)
The Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6 with αEvolve Imaging (FOV Extension), is an interventional X-ray system with a floor mounted C-arm as its main configuration.
AlgorithmArtificial Intelligence Denoising (AID)
source quote (p.7)
αEvolve Imaging is an imaging chain intended for adults, with Artificial Intelligence Denoising (AID) designed to reduce noise in real-time fluoroscopic images and signal enhancement algorithm, Multi Frequency Processing (MFP).
Adaptive (vs locked)FDA source did not state this
PCCPNo
Cybersecurity addressedYes
source quote (p.11)
Cybersecurity documentation followed FDA cybersecurity premarket guidance document “Cybersecurity in Medical Devices: Quality System Considerations and Content of Premarket Submissions” issued on September 27, 2023.

Validation studies (1)

Bench

sample size not stated

endpoints: Change in Image Level, Noise Magnitude and Signal-to-Noise Ratio (SNR); Noise Power Spectrum; Noise Texture via Kurtosis; Modulation Transfer Function (MTF); Noise Equivalent Quanta; Low Contrast Detectability; Contrast-to-Noise Ratio of a High Contrast Object

standards: IEC 60601-1:2005+A1:2012+A2:2020, IEC 60601-1-2:2014 + A1:2020, IEC 60601-1-3:2008+A1:2013+A2:2021, IEC 60601-1-6:2010+A1:2013+A2:2020, IEC 60601-2-28:2017, IEC 60601-2-43:2010+A1:2017+A2:2019, IEC 62304:2006+A1:2015, IEC 62366-1:2015 + A1:2020, IEC 81001-5-1:2021, ISO 17664-2:2021, IEC TR 60601-4-2:201, IEC 62220-1-1:2015, ISO 13485

Reported performance (0 observations)

FDA source did not state a quantitative performance metric — non-reporting is itself the signal.

Each value carries its own analysis unit and task — never compare or pool across devices. Source: 510(k) summary PDF.

Predicate network

Postmarket — what happened after clearance

100
recalls in product code, 24mo
10937
MAUDE reports in code, 12mo
+44%
vs code's own 3-yr baseline
7
drift signals on this device
  • recall_reason_pattern

    Software/algorithm-related recall in product code OWB (Siemens Medical Solutions USA, Inc, initiated 2026-05-20): "Potential for loss of movement capability after adjusting the detector lift height to its maximum or minimum limits." Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:99079

  • recall_reason_pattern

    Software/algorithm-related recall in product code OWB (Medtronic Navigation, Inc.-Boxborough, initiated 2026-05-19): "Potential for image artifacts caused by an anomaly in the O-arm O2 Imaging System s detector panel firmware." Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:99041

  • recall_reason_pattern

    Software/algorithm-related recall in product code OWB (Siemens Medical Solutions USA, Inc, initiated 2025-12-29): "Ortho images acquired with preset automatic horizontal flip are not flipped and when acquiring single images, there is the possibility that an image of a previous patient may be pr" Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:98244

  • recall_reason_pattern

    Software/algorithm-related recall in product code OWB (PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. Veenpluis 4-6 Best Netherlands, initiated 2025-12-12): "Six (6) identified software issues which may result in the following: system keeps restarting, AMC triple drive, C-Partition of Suite PC running out of free space, system remains i" Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:98096

  • recall_reason_pattern

    Software/algorithm-related recall in product code OWB (PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. Veenpluis 4-6 Best Netherlands, initiated 2025-12-12): "Philips has identified two (2) software issues affecting device systems that may result in loss of imaging (X-ray) functionality and/or loss of motorized movement, and/or incorrect" Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:98108

  • recall_reason_pattern

    Software/algorithm-related recall in product code OWB (PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. Veenpluis 4-6 Best Netherlands, initiated 2025-12-08): "Nine (9) identified software issues which may result in the following: loss of X-ray after Pedal Tap, loss of X-ray after Phase Fault, missing live X-ray on the FlexVision monitor," Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:98071

  • …and 1 more.

Recall and MAUDE counts are product-code-level (reports aren't reliably attributable to one device). Signals are descriptive observables with sources — never a judgment that the device is unsafe or drifting. Snapshot 2026-07-08.

Reimbursement — how devices like this got paid

Not yet tracked — no payment pathway indexed for this clearance (the reimbursement corpus is a growing seed set).

RIGOR™ Precedent · public FDA/CMS data · descriptive decision-support, not regulatory or reimbursement advice. Share this page: radar.healthai.com/precedent/device/K253584