Lung Density Analysis

K141069

IMBIO LLC · cleared 2014-09-17 · product code JAK · Radiology

Premarket evidence — what FDA accepted

Device typesamd
source quote (p.5)
The Imbio CT Lung Density Analysis Software (Imbio LDA) is a set of image post-processing algorithms that perform image segmentation, registration, thresholding, and classification on CT images of human lungs.
AlgorithmImage post-processing algorithms that perform image segmentation, registration, thresholding, and classification on CT images of human lungs. The program performs segmentation, then registration, then thresholding and classification. It analyzes DICOM CT lung image datasets and generates reports and DICOM output that show the lungs segmented and overlaid with color-codings representing the results of its thresholding and classification rules.
source quote (p.5)
The Imbio CT Lung Density Analysis Software (Imbio LDA) is a set of image post-processing algorithms that perform image segmentation, registration, thresholding, and classification on CT images of human lungs. The algorithms within the Imbio CT Lung Density Analysis Software are combined into a single command-line executable program that may be run directly from the command-line or through scripting. The Imbio CT Lung Density Analysis Software program performs segmentation, then registration, then thresholding and classification. The program reads in DICOM datasets, processes the data, then writes output DICOM files to a specified directory. The Imbio CT Lung Density Analysis Software is a command-line software application that analyzes DICOM CT lung image datasets and generates reports and DICOM output that show the lungs segmented and overlaid with color-codings representing the results of its thresholding and classification rules. It has simple file management functions for input and output, and separate modules that implement the CT image-processing algorithms.
Adaptive (vs locked)FDA source did not state this
PCCPFDA source did not state this
Cybersecurity addressedFDA source did not state this

Validation studies (2)

Bench

sample size not stated

endpoints: scan processing completion; segmentation; thresholding

Standalone

sample size not stated

endpoints: software verification and validation testing for each requirement specification; software verification and validation testing for each algorithmic function; software verification and validation testing at the unit, integration, and system level

Reported performance (0 observations)

FDA source did not state a quantitative performance metric — non-reporting is itself the signal.

Each value carries its own analysis unit and task — never compare or pool across devices. Source: 510(k) summary PDF.

Predicate network

Postmarket — what happened after clearance

75
recalls in product code, 24mo
192
MAUDE reports in code, 12mo
-22%
vs code's own 3-yr baseline
9
drift signals on this device
  • recall_reason_pattern

    Software/algorithm-related recall in product code JAK (GE Medical Systems, LLC, initiated 2026-03-26): "GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with " Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:98738

  • recall_reason_pattern

    Software/algorithm-related recall in product code JAK (PHILIPS MEDICAL SYSTEMS, initiated 2026-03-07): "Philips has identified three software issues: 1. During a continuous CT (CCT) scan, there is the potential that the Gantry could remain at the current scan position after pressing" Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:98588

  • recall_reason_pattern

    Software/algorithm-related recall in product code JAK (Siemens Medical Solutions USA, Inc, initiated 2025-12-19): "To remove the software applications from certain CT systems as the applications have not received FDA 510(k) clearance." Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:98206

  • recall_reason_pattern

    Software/algorithm-related recall in product code JAK (PHILIPS MEDICAL SYSTEMS, initiated 2025-09-25): "Issue 1: The potential for unintentional continued gantry/couch movement when a specific button series is used requiring use of manual stop. Issue 2. When performing a helical/Axia" Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:97699

  • recall_reason_pattern

    Software/algorithm-related recall in product code JAK (Philips North America Llc, initiated 2025-05-29): "Devices with affected software may experience two unintended motion issues that may lead to contact between the Gantry or table with the operator or patient, along with additional " Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:97010

  • recall_reason_pattern

    Software/algorithm-related recall in product code JAK (, initiated 2025-05-23): "Due to a software bug the robotic arm may incorrectly guide the instrument compared to the planning defined by user." Recalling firm is another firm in the same product code.

    first seen 2026-07-08 · recall res_event_number:96967

  • …and 3 more.

Recall and MAUDE counts are product-code-level (reports aren't reliably attributable to one device). Signals are descriptive observables with sources — never a judgment that the device is unsafe or drifting. Snapshot 2026-07-08.

Reimbursement — how devices like this got paid

Not yet tracked — no payment pathway indexed for this clearance (the reimbursement corpus is a growing seed set).

RIGOR™ Precedent · public FDA/CMS data · descriptive decision-support, not regulatory or reimbursement advice. Share this page: radar.healthai.com/precedent/device/K141069